So we divide the 10kw, by 230 volts =43. If their is an outlet plate on the wall behind the original cooker position, you can connect to this with the 2 extra cables. 29 Inc Vat. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. Screwfix Community Forum. Repair Service Action. £72. Boost function. 5mm 3 core flex. Add to wishlist. stateit Screwfix Select. com. What is the standard way? Is it just a 6/10mm radial fed by a 32a MCB/RCBO, then onto a 45a DP switch above worktop, then onto a dual 45a plate outlet, then 2 feeds one to hob other to cooker?. 95 Inc Vat. READ NEXT: Best gas hobs. 2 x Plate Sizes. 60a - 10a = 35. White PVC Sheathed Cable. Buy Domestic Electricals at Screwfix. Number of Cooking Zones: 2 Zones. Timer. com. 1/5. From £9. If the whole area is grimy, then use a toothbrush with the WD40 to clean thoroughly around the button shaft and wipe it clean. I have a new 13 amp oven coming which will have a three pin plug & a. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. 95 Inc Vat. Cooke & Lewis CGSBCER60 560mm Ceramic Hob, Hood & Splashback Black (145KH) compare. Some hob manufacturers differ from these dimensions. To assess the loading of the hob and oven do the following. Discussion in ' Electricians' Talk ' started by Monguy, Feb 3, 2022 . 9KW - new electrical oven is: 3. s black glass design with an easy clean surface for quick maintenance, a timer for accurate cooking, auto safety switch off and a safety key lock to prevent accidents and overspills. Screwed Faceplate. #4. Hi, we're looking to change out our gas hob for an electric model, as we've recently had a gas leak and the cost of getting the gas back in working order in the kitchen seems to be way higher than disconnecting the gas and running a new electric hob. Regulation height from top of hob to bottom of extractor is for Gas - min 750mm and for electric min 700 mm. The Sigma3 countertop depth is the standard 600 mm but the splashback thickness (approx 15 mm) clearly reduces the useable depth to less than the minimum 600 mm required by Neff. Buy Electric Hobs at Screwfix. Safety Gas Cut-Out. View product Smeg SI4642D_BK 60cm Electric Hob - Black £. 99Inc Vat. The fridge was pretty tight to the bottom of the kitchen top and the bottom of the hob was pretty much flush with the bottom kitchen top aswell. Quick installation via an existing socket or alternatively can be hard wired by a qualified electrician for full functionality. My electric Zanussi hob has recently started tripping the mains electric. PVA/waterproof varnish/paint. The circuit supplying your existing oven will most likely be a standard 32A cooker circuit wired in 6mm2 T&E. I phoned a NAPIT electrician. £72. Choose options. 5mm H05 flex for oven to outlet plate as specified in manufacture manual says the max wattage for this size cable is 3860w. Buy online and collect in stores nationwide. Currently have a built in electric oven which is hard wired in to the cooker switch & socket, and a gas hob with elec spark which is plugged in to a 2 gang socket in an adjacent cupboard. Page 2 of 2 < Prev 1 2. Its a good bet that the socket will fail after some use. Discount applied in basket. Almost all of the ovens/hobs I have installed recently have specified the breaker and cable size. Bob Rathbone Screwfix Select. seneca Screwfix Select. If you have blades which cut on the upstroke, then you should lay the worktop upside down and cut that way. 5Kw (14. 16th edition. Pay your way. . is 680502. W x H x D: 260 x 90 x 7mm. Buy any 10+ Save 10% - View Offer. View all: Unika Worktop Fittings. But if i turn the isolator switch on with the hob disconnected its fine. Dan Parkinson, Jul 27, 2020. You simply use a standard cooker circuit. Should the product require repair please contact our repair service to arrange collection and repair. There most certainly is regarding gas hobs, unless the sink is stainless steel or vitreous ceramic, it has to be a minimum of 150mm from the edge of the sink. Plug the new oven in. 4. British General 900 Series 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket White (56392) (39) compare. Customer complained she couldn't use the oven and hob at the same time as the fuse kept blowing. Each of the ovens is 5. If the hob is relatively new, don't use silicon as it will probably invalidate the manufacturer's guarantee. Shop now. Hans_25 Screwfix Select. I’d be surprised if it didn’t fit. Delivery. mb New Member. 5 mm flex. FREE next day delivery available, free collection in 1 minute. CDA 30cm 2 Zone Domino Ceramic Hob. Even heat distribution. The technical data states, conductors (number & size)3 x 2. ElecCEng, May 29,. On the new Beko hob it simply states use 5x1. Any advice appreciated. Neither have any cables attached, but both state 4mm cable on the connection points. Is it OK for an electric hob to touch wood struts directly underneath? 2. Dr Bodgit Super Member. I cant work out if the Hob will fit over the top of the oven with just 20mm worktop. However, the oven will still not fit because of a pipe coming down from the hob itself. Without me having to look for the model of my Neff (100cm) induction hob, I needed to run a 10mm cable for it to work at full capacity. Order : 45a switch > dual appliance outlet > outlet 1) oven, outlet 2) 13a. Write a review. But there's not the prescribed 15mm of space between the oven and worktop - it's covered with a small wood panel that's started to fall down on one side. Plug In and Go. 5kW. Timer. The radial circuit already exists and the cable used is the correct guage for the load. 500062. Discussion in 'Electricians' Talk' started by alex250, Aug 1, 2004. I am pretty sure my electric hob had terrminals that you could connect the oven to. £438. 00. britishblue New Member. 56 Amps total, with diversity. 6. furious_customer, Oct 2. I do not know of any electric hob that will utilise a 13amp plug . com. All on a 40amp breaker or would it be best to de-rate down to. com. 04 amps then add the the first 10 amps back on, total with diversity taken into account = 20. 1 x Ø 380 mmx230 mm, 3. Apple Pay accepted in store. It also says 380 to 415V between L1 and L2. Page 2 of 2 < Prev 1 2. 5 mm flex seemed a bit lightweight for the hob. We have a set of three stainless steel pans designed for induction hobs ( ironically we'd bought these years before we went induction simply because they were nice pans at a bargain price ), traditional plain cast iron ones & some. This stainless steel hob is compact and lightweight, and has variable independent heat control and power on the two separate cooking plates: 1500W and 750W. 3/5. rogerk101 Screwfix Select. It's a new build, only 4 years old and has been fine. I've checked the voltage being fed to the hob outlet and its 240v on the live and 0 on the neutral. Stainless steel finish. Touch-Dry in 1-2 Hours. Apple Pay accepted in store. British General 900 Series 13A 2-Gang SP Switched Plug Socket White 5 Pack (48563) (62) £13. The oven circuit is fused at 32A. Discussion in ' Plumbers' Talk ' started by Peter160482, Mar 14, 2021 . Bush BIBCP 60cm Multifunction Single Oven. Miele KM7201FR Electric Induction Hob - Black. Two out of four elements in my electric hob have gave up the ghost. That way you are not only testing it for functionality (like it heats up) but also the RCD will trip idf there is an earth leakage fault. I'm currently changing my hob for a new one. Electric hobs are compatible with any material but it’s important the bottom of. 1kW and we’re installing a new dual fuel range oven rated at 8. You need to read it properly: The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 55cm from electric cookers and 70cm from gas or mixed cookers. Only the sealing strip can be used. If your splitting the hob & oven then yes I would use a connection unit for each appliance. Buy Kitchen Appliances at Screwfix. Samsung NZ84F7NC6AB_BK 80cm Electric Hob - Black (2) £ 818. 00. What there is though is manufacturers fitting instructions, which should include the minimum distance from combustible material. 2kW (44A) 10mm cable. 7 kW into a single ring, where the 13A socket can only. #3. 5mm, does this mean I use a 2. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. Bob Rathbone Screwfix Select. The hob comes with a 13amp plug so all that is needed is for her to plug this into an adjacent wall socket. alex250 New Member. 9Kw/32amp and hob is at 11. oven spec: -cable type must be a minimum of ho5vv-f (pvc insulated and sheathed) 3 cores x 1. Would it be possible to install it on our existing power setup for the oven?recently wired a cooker supply expecting there to be a gas hob and oven . Ask a question. I know this has been posted before but just wanted to clarify a few points. Buy any 10+ Save 10% - View Offer. Odourless. Or poke the seal strip back just under the hob with a blade laid flat. My question is the installation guide states is should be "connected using 3 x 6mm / 3 x 2. I have bought a new kitchen. Is there a minimum distance required between the back of the electric oven and the copper gas pipes. Current oven is connected to a 16amp mcb at the fuse box,question is can I connect all 3 new units to this 16amp mcb,once theold oven is disconnected. 5-amp electrical outlet. 4. The reference code for this accessory. If you really want a 5 ring ceramic/induction hob, you will have to hire a Quartz fitter to make the cutout wider. (24) From £249. I originally thought this meant to use either 5 or 3 cables. Hob Type: Induction Hob. The MK one in your second link is only for one cable going out. Free returns. 2 x Plate Sizes. Stainless steel finish. I just thought 2. I feel like I should take the hob out and put some sort of tape/barrier round. 2 KW (max. Most sockets feeding things like dishwashers and washing machines are mounted inside an adjacent cupboad. Repair Service Contact. The gas connection will be done by a suitable gas engineer but currently shopping for gas hob. I can't fit the brackets as the underneath edges of the hob are sat too close to the wooden struts. 2) 220-240V 2 ~ H05V2V2-F 3G 2. 4 x Burners. Ideally you need an electrician who is capable of undertaking kitchen fitting and knows a gas fitter. The pan base heats up. unphased, Oct 2, 2018 #21. Plus - gas hobs rarely if ever go wrong, bar the igniters, but even these are infinitely more reliable than any type of electric hob. Child /. I hope this the right thread. Instructions say hob must be connected to a fused spur outlet with 3A fuse and oven must be connected to a fused spur outlet with 13A fuse (using 1mm cable). 2 x Ceramic Plates. The circuit supplying your existing oven will most likely be a standard 32A cooker circuit wired in 6mm2 T&E. Both the ElectricOven (2. Both are RCD protected. Both the old and new hob are rated at 5. Now take the first 10A and 30% of the remainder =11. Ah no. 5 flex wil take 18amps, from the ccu you should run 6mm to a cooker connection plate then use 6mm from here to the hob, although they supply it on some and for the cooker, what size is it the max for a fcu is 3120wattsI am going to fit my Baumatic 636. Remove the cooker connection plate and replace it with a single socket. As you probably know, induction hobs work by turning electricity into magnetic currents that in turn agitate the food molecules in the pan, not by actually heating the pan. Dan dan the man Active Member. £7. Hi, I've managed to smash my ceramic hob with a bottle of olive oil of all things. Hi everyone. It goes straight down into the ground, underneath the kitchen floor tiles, over to the other side of the kitchen where it. #5. 1 x 59 x 52 cm (H x W x D) 4 zones. Flexible delivery available. Plug In and Go. the thicker one is the hob. It has starting getting small cracks in the worktop around the edge of the hob next to the ring I use the most. Screwfix Community Forum. Bob C New Member. Ah ok so it's the same wiring as an electric hob, but slightly more complex is that right? HannahBanana, Sep 13, 2017. Buy Hobs at Screwfix. I too am wanting to do this. Is is normal practise to wire both appliances into the outlet that is supplied by the 45A DP cooker switch on the wall? I appreciate your time if you can. Several options available. 95 Inc Vat. Pay no interest when you pay your full balance within 9 months 29. Its always better to have these sorts of load on a dedicated circuit. Pay your way. Buy online and collect in store in as little as 1 minute. Oven and hob packages. 27 Strands Per Core. A good induction hob will draw 40A or more. Apart from this risk of the entire hob detaching and dropping into the cupboard below, (potentially tipping a pan of boiling water down your lower body causing life changing injuries) moisture could be making its way into the electrical. I don't think so, the hob is currently gas and the oven electric just plugged in to a double socket at the back. It's a heavy base wok so distributes heat evenly unlike a thin carbon steel wok. The oven is fitted with heavy duty 2. Buy Cooker Switch Switches & Sockets at Screwfix. could it be wrong MCB rating, faulty MCB? any advice much appreciated cheers, SamDepends on the type of clips/clamps they send with the hob then. Hi, I would like to replace an existing electric oven & gas hob with a new electric oven & electric hob. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. #4. 29 Inc Vat. SW1V 1AA. #2. PAGE 1 OF 12. 9Kw/32amp and hob is at 11. High Dielectric Strength. Total 40 amp. 5MM2. Electrical Connection 7. If it is 7000W, this would be 29A at 240V, so 4mm2 flex (which could theoretically handle about 32A) should be OK. Timer. Child Safety Lock Mechanism. The AEG Pure 3 hob combines a sleek, seamless design with responsive functions. Delivered by our approved supplier, Find out more. It's explained in the hob manual. The display on the touch control panel is fine. PayPal accepted online. (13) £. oven and hob are both electric hob has electric plates. Raised Square Profile. It took me some time to work out what had casued it (none of the independant switches had tripped) but it wouldn't re-set. com. Bazza, Feb 4, 2022. rogerk101 Screwfix Select. Repair Service Action. We have 6mm T&E from the CU to a hob isolator switch on the kitchen wall. Discussion in 'Electricians' Talk' started by jasondo23, Dec 6, 2009. com. Add to basket. 2 x Ceramic Plates. Automatic switch-off timer and up to 9 adjustable power levels per zone. Raised Square Profile. 29 Inc Vat. Electric hob question - Help : o. Lee58 New Member. I intend to replace the single cooker by separate hob and grill/oven units with a total power consumption intended to be no more than the existing cooker. If it has a plug, add a 13A socket to the cooker circuit. Instant heat and easy to manipulate to the required temperature. Use either the 6mm cable to connect the 2 items, or use heat resistant 2. Number of Cooking Zones: 4 Zones. Click & Collect. Hi all. com. £11. Ceramic Hobs and Electric Ovens Installation. Oven is only rated at 2. Perhaps I should persuade the my mother-in-law to get a decent electric hob ! Sam, Jun 16, 2006 #5. Hi, I have some rust on the trim around my electric cooker top and I would like to try and repair it. So both will be off the same feed using this in cupboard next to cooker/hob. Add to basket. Discussion in 'Electricians' Talk' started by SpuddyMcFuddy, Nov 14, 2017. My question is. Bosch PCP6A6B90 58cm Gas Hob - Black. The existing hob is connected to its own plug socket. ProDave New Member. Induction hob featuring Autoconnect technology LinkSense, allowing wireless RF connection to compatible hood. we have a solid laminate worktop and upon reading the guide (after fitting!) I note we should have lowered the ovens by 20-25mm. 82 would be the total loading, yes 10mm ok with a 40amp breaker. Fuse Rating 16 Amps. I would prefer to have oven and hob on cooker circuit, then separate 20a circuit for microwave, which could also accommodate extractor hood too. €91. Requires 46mm Back Box. LAP 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket Black Nickel with LED with Black Inserts (96338) (22) compare. 4 Kw total load induction. I I guess I put both lives in the live and both neutral in the neutral the. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. 56A) = 20. It appears the only the (steel) saucepans on top get heated so the only heat coming downwards would be limited to the temperature of the saucepan (around 100 degC) as there is no 2. com. 6 So my cooker circuit is not adequate enough. 6 x 49. Yes, they would work perfectly well if plugged in on a 13A socket but the circuit would quickly overload when other appliances were plugged in. There must be gas regs about this sort of thing surely. You could fit a plug to the hob with a 13A fuse in it. Induction hob / electric oven. Allow to dry between coats. 2 x Plate Sizes. So I am wondering does diversity apply to the combined total wattage of both the appliances or just the oven. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. Choose options. P=Power, V=Volts, and I = amps P = V x I P/V = I 8800/240 = 36. 29 Inc Vat. Discussion in 'Electricians' Talk' started by wrighty wrongy, May 2, 2016. Crabtree Capital 20A 1-Gang DP Hob Switch White (7483J) compare. 5MM2. 5KW and I have put it on a 32A breaker, with 6mm cable. In the main an electric hob needs letting into the work top, where a gas one has a recess in the design to catch spills, what you don't want is for the spill to run off the hob onto the work top making any items on the work top wet, my induction hob is around a 1/16 of an inch lower than work top. So I changed the single socket into a double to get rid of the extension lead which was a fire hazard to begin with. Power level 3. Both the hob and the oven can pull their maximum current of 2 x 13 amp (26amp). £36. 30 day money back guarantee. kitchen appliances. The regs allow a separate oven and hob to share the same supply and control unit provided that they are not more than 2 metres apart or from the control, that you apply diversity, that is you add the hob and oven current together, take the f1rst 10A of that total and add 30% of the remainder (add 5A if a socket is fitted to the cooker control, don't do. com. If the drainer is on the Hob side, then I'd be OK with it at 200mm. 6a = 24. I have had a new aeg gas hob fitted. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. Choose options. stateit Screwfix Select. com. More precise cooking. Wide range available. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of storesHi mate thanks for reply im trying to avoid anymore cost if i dont have to, this house has already cost me enough lol, im guessing the pipe is ok but if your saying it 100% needs a gas safe engineer to cap it then i will get it done, but if your not sure then im trying to get a gas safe engineer to tell me if it needs it or not before i fit the electric hob, hope. #7. Power level 3. Ozwald Cobblepot Member. An induction hob is an electric hob, just has an increased power rating (normally) Dr Bodgit, Sep 13, 2017. Let’s Go! Next day delivery, 7 days a week. Black PVC Sheathed Cable. 49 Inc Vat. Also the supplied cable for the oven seems a bit lightweight to put into a connection plate. 5m The oven has a cable with a 13amp fuseHome Forums > Screwfix Community Forum > Electricians' Talk > Electric hob & cooker connection. Supplied in a variety of fuel options, this type of equipment is easy and simple to use and has different configurations available to get the best fit for a design. 98 Inc Vat. The product manual does not state the cable size to the hob, only that it should be H05BB-F or H03V2V2-F.